Scientific Reports volume 12, Article number: 7689 (2022) Cite this article 1675 Accesses 3 Citations Metrics details This article deals with the comparative analysis of current cable force monitoring

Scientific Reports volume 12, Article number: 7689 (2022) Cite this article

1675 Accesses

3 Citations

Metrics details

This article deals with the comparative analysis of current cable force monitoring techniques. In addition, the experience of three cable stress monitoring techniques during the construction phase is included: (a) the installation of load cells on the active anchorages of the cables, (b) the installation of unidirectional strain gauges, and (c) the evaluation of stresses in cables applying the vibrating wire technique by means of the installation of accelerometers. The main advantages and disadvantages of each technique analysed are highlighted in the Construction Process context of the Tajo Viaduct, one of the most singular viaducts recently built in Spain.

One of the solutions proposed by civil engineers to overcome large spans is to use cable-stayed or suspension bridges. The critical component of these structures lies in the vulnerability of the cables to problems or damage associated with fatigue and/or corrosion1 caused by dynamic loads such as cyclic traffic loads, wind loads, and other operational loads as well as environmental effects2. Structural Health Monitoring Systems (SHMS) are a very useful tool for the maintenance of structures. One of the main phases of SHMS design is to identify the parameters that define the behavior of structures3,4. Temporary suspension cables for constructive phase present the same problems and it is at this phase that the article looks in more detail at.

The most important parameter for the assessment of stress, and fatigue and corrosion damage of cables in service is the historical record of the axial stress over time of these structural elements. This parameter has been recognized as a useful indicator of damage by safety condition of stay cables and also suspension cables in bridges5, and real-time monitoring of this indicator has become essential for the assessment of possible fatigue damage in these structural elements. For this reason, monitoring and assessment of structural performance has become standard practice to ensure the safety and durability of cable-stayed or suspended structures6,7,8,9.

Several types non-destructive testing are used to diagnose the safe condition of stay cables in bridges9, such as ultrasonic testing, the magnetic flux leakage detection technique10, or X-rays. Although effective, these techniques are more suitable for the assessment of out-of-service stays.

On the one hand, various devices have been developed for the direct measurement of strain in bridge cables, such as load cells9,10,11,12,13,14,15, optical fibre Bragg grating sensors16, or elastomagnetic strain sensors17,18.

These sensors are able, thanks to their specific technologies, to accurately determine the stress experienced by the cable, and, when connected to a Structural Monitoring System (SMS), it is possible to create a long-term historical record of cable stresses as well as to access this data in real time from any remote location.

On the other hand, the most common indirect methodology for the rapid assessment of bridge cable stresses is the vibrating wire technique. This method is based on the relationship between cable stress and its vibration frequency, which can be correctly identified from the recording of accelerations during free vibration of suspension cables19,20,21,22,23,24. The application of this method requires the use of spectral decomposition techniques that allow for a real-time determination of the stresses in the suspension cables in bridges by identifying the vibration frequencies during a free vibration regime25,26,27,28,29,30,31.

There are many types of sensors for each of the measurement techniques32,33,34,35.

Electronical sensors transform the measurement (parameter to be measured) into a change in voltage, current, resistance, capacitance or inductance. Electrical sensors come in many varieties and are often very simple to interface to any datalogger system. Examples include potentiometer displacement sensors, resistive strain-gauges, load cells, MEMS36 tiltmeters and piezoelectric sensors. Electrical sensors are often relatively inexpensive but can be subject to drift and can be affected or damaged by electromagnetic disturbances such as power lines.

Vibrating Wire (VW) sensors37 transform the measuring into a chance in the vibration frequency of a wire. In the case of VW strain sensor, a change in strain results in a change in the tension of a steel wire, while in the case of VW piezometers the deformation of a membrane due to a change in water pressure also induces a change in the tension of the sensor wire. Once the wire is excited by an electromagnet, it is possible to accurately measure its vibration frequency. The frequency measurements are very accurate and stable, which is why these sensors have become a standard for accurate long-term measurement in geotechnical and structural monitoring.

From many points of view, optical fibre sensors38 are the ideal transducers for structural health monitoring. These sensors transform the quantities to be measured into a change in the propagation characteristic of the light travelling through the optical fibre. Being durable, stable and insensitive to external disturbances, they are particularly useful for long-term health assessment of civil structures and geostructures. Many different fibre optic sensor technologies exist, including Fibre Bragg Gratings, SOFO Interferometer, Fabry Perot Interferometer and distributes Brillouin and Raman sensors, and offer a wide range of performances and suitability for different applications.

In the early 1990s, fibre optic sensors made a major entry into the sensor industry and now have an established presence in the structural sensing industry39.

Distributed fibre sensors40,41 represent a paradigm shift in terms of monitoring and sensing. Distributed sensors are able to detect at any point along a single standard telecommunication fibre optics, which allows discriminating different positions of the measured parameter along the fibre, transferring strain and temperature from the structure to the fibre.

Distributed sensors are specially recommended42 for detecting and discriminating events at any point within a structure.

These techniques are particularly useful for monitoring the global movements of structures43. They include traditional geodesy methods, total stations with or without target prisms installed on the structure, laser distance meters and laser profilometers as well as terrestrial radars (including synthetic aperture radar). Those techniques can be sued for example, to measure the deformation of a bridge, the movement of a tower, the progression of a landslide or the deflection of a dam.

Olaszek44 developed a method that incorporated the photogrammetric principle with computer vision technique to investigate slow dynamic characteristics of bridges.

Patsias and Staszewski45 and Yoshida et al.46 started the use of videogrammetric techniques to measure mode shapes of a beam and to capture the 3D dynamic behavior of different structures. Chung et al.47 used digital image techniques for identifying nonlinear characteristics in more complex structural systems. Chang and Ji48 developed a two-camera videogrammetric technique for measuring a 3D structural vibration response at laboratory level. In49, Ji and Chang proposed a novel nontarget technique based on image analysis using one digital camera for cable vibration measurement but, again, it is a proof-of-concept.

These techniques, although promising and most of them verified at laboratory level or under controlled conditions, do not seem to provide complete dynamic information, only a part of the free vibration. Therefore, application during construction must await a more advanced level of development.

The Tajo River Viaduct belongs to the Madrid–Extremadura high-speed rail. It is located in the province of Caceres and has a total length of 1488 m. Its span distribution is determined by the width of the Tajo River, over which the arched viaduct spans 324 m. The above deck is divided into six spans of 54 m each. The access spans are 60 m long, with two 57 m transition spans between them and the deck spans above the arch. The results in an appropriate and harmonious distribution of the 26 spans that make up the Tajo River Viaduct deck: 45 m + 9 × 60 m + 57 m + 6 × 54 m + 57 m + 7 × 60 m + 45 m50,51.

The layout of the viaduct presents a very wide curve and then a straight line throughout the rest of the bridge. The most emblematic element of this viaduct is the arch, with a span of 324 m between its supports, which rises above its foundations to a height of 70 m and above the maximum level of the Alcántara Reservoir to a height of over 80 m.

The arch was built using the technique of successive cable-stayed cantilevers, with two temporary towers placed on the piers on both banks of the river (see Fig. 1). Each tower was braced to the foundations of the neighboring piers, so it was necessary to provide these foundations with the prestressed ground anchorage units. For the arch construction phase, fifteen pairs of cables supported each half full arch, and a further fifteen pairs supported the tower. The length of these cables ranged from 80 to 180 m.

Tajo River Viaduct during its construction.

Each half arch is made up of a total of 46 segments, each of 4 m long. The concreting trolley is a metallic element that supports the formwork of each segment and its concreting. This trolley was placed in the area of the arch that had been concreted most recently, in order to prepare for the concreting of the next segment.

Once the arch was completed, the temporary cable system consisting of the temporary towers, cables and ground anchors was dismantled. At this point, two adjacent piers were built on either side of the arch which, together with the segmental, support the deck above the arch. The deck was built span by span using self-supporting formwork from both abutments. To avoid creating excessive stresses in the arch, the deck was concreted symmetrically and allowed for a maximum displacement of only one span.

During the structural monitoring of Tajo River Viaduct, three methodologies were used to monitor the tension in the temporary suspension cables of the main span arch-type: (a) strain gauge installed in the active anchorage of the temporary cables, (b) unidirectional strain gauges installed in one of the seven wires belonging to one of the cable strands, and (c) cable instrumentation by means of a unidirectional accelerometer.

The strain gauge load cells designed by the authors for the instrumentation of the temporary cables of the Tajo River Viaduct consisted of a metal ring between the cable anchor plate and the distribution plate on the pile or temporary tower. Due to the dimensions of the suspension cables, the average diameter of the load cells of the Tajo River Viaduct varied between 200 mm for the least loaded cables (2000 kN) and 500 mm for the most loaded cables (5500 kN) (see Fig. 2).

Tajo River Viaduct load cells: (a) pier load cell; (b) load cell in temporary stay tower.

This technology makes it possible to determine the strain in the stay cable from the empirical characterization of the mean normal strain in the central ring of the load cell, see Eq. (1). For this purpose, the outer perimeter of the central ring is instrumented by the uniform distribution of bi-directional strain gauges connected in series by a full Wheatstone bridge configuration52,53,54,55.

where F = Stress in the suspension cable; σ = Normal stress; dΩ = Differential area at the central ring; ɛi = Normal strain at the ith strain gauge; n = Number of strain gauges; Ea = Modulus of elasticity of steel; Ωc = Area of the central ring.

The load cells installed on the cables made it possible to certify the correct tensioning of the cable families and to characterise, in real time, the variations in the stresses experienced by the suspension cables during the different phases of the construction process (see Fig. 3). These devices made it possible to detect any of the following structural phenomenon occurring during the construction process: (1) the variation of stress in the cable due to the daily thermal increase, with stress increases of around 150 kN for daily temperature variations of 30 K (30 °C); (2) the stress variations due to the concreting of successive segments, with stress variations that could range from 200/300 kN in the cables closest to the concreted segment, to values lower than the daily variation in the cables furthest away; (3) the stress increases due to the tensioning of the successive families of cables (see Fig. 4), with stress variations greater than 500 kN in the families closest to the cables placed under load, and less than the daily variation of the load in the families furthest away; or (4) stress variations due to load readjustment operations in cables.

Recording the evolution of stresses in the retaining cables of the northern semi-arch: (a) 2nd cables family; (b) 4th cables family; (c) 6th cables family; (d) 8th cables family; (e) 12th cables family; (f) 14th cables family.

Evolution of the stress experienced by the eighth retaining cables family.

Figure 4 shows the evolution of the stress experienced by the stay cables of the eighth family. This graph shows the evolution of the stress characterized by the load cell installed in one of the rear stay cables, as well as the evolution of the theoretical stress predicted by the theoretical calculation model. The evolution of the stress experienced in the provisional stay cables of the eighth family, caused by the concreting of the successive arch segments can and the tensioning of the successive families of cables, can be clearly seen.

Figure 3 shows the evolution of the stress experienced by the different families of the retaining cables of the northern half arch and their comparison with the theoretical values of the project during all the construction phases of the main arch span, while Fig. 5 shows the evolution of the stresses in the suspension cables of the northern half arch during the loading of the cables corresponding to the 13th family of temporary cables.

Recording the evolution of stresses in the stay cables of the northern semi-arch during tensioning of the thirteenth cable family: (a) 3rd cable family; (b) 5th cable family; (c) 7th cable family; (d) 9th cable family; (e) 11th cable family; (f) 13th cable family.

The values provided by the instrumentation of the provisional stays of the Tajo River Viaduct allowed the calculation models to be continuously updated with the reality of the construction site. The comparison and updating of the theoretical/empirical values made it possible to readjust the load values in the stay cables in the event of large deviations.

During the instrumentation of the cables corresponding to the first two families of temporary cables, the authors detected that the edge initially given to the strain gauge load cells was not sufficient to minimise the error induced by the irregularities in the boundary conditions. It was necessary to complement these sensors with other types of sensors to characterize the strain variations in the cables. It was decided to install two unidirectional strain gauges on one of the seven wires that make up one of the strands, connected together using a full Wheatstone bridge configuration52,53,54,55. This technology allows for the instrumentation of cables once loaded and enables the empirical characterization of the strain increases experienced by the cable.

The steel wires that make up the strand are twisted together so that the directrix of these wires has a certain angular deviation with respect to the strand directrix (see Fig. 6). This fact makes the recovery of the strand deformation from the wire deformation indirect, and implies the need to perform the calibration of the measuring system in a tensiometer where the kN/µɛ correlation between strand tension and the wire deformation can be obtained (see Fig. 7). The tensioning of the provisional stay cables of the Tajo River Viaduct was carried out using the isotensioning technique56. This technique makes it possible to obtain identical tension in each of the strands that make up each stay cable. However, it is advisable to instrument several strands of the same stay cable in order to obtain an optimum measurement of the tension in the stay cable.

Installation of unidirectional strain gauges on one of the wires of a strand in a temporary cable.

Calibration of the cable instrumentation method by the installation of unidirectional strain gauges: (a) prestressing strand in load-bearing gantry; (b) load/deflection curve during calibration test.

The simultaneous instrumentation of the first two families of stay cables by means of load cells and unidirectional extensometers installed in one of the strands composing the stay cable provided a double contrast of the value of the stress value experienced by these structural elements. Figure 8 shows the evolution of the stress value in the instrumented stay cable of the fourth family provided by the load cell (CNT-4), by the extensometers (CNT-4_ext) and by the theoretical calculation model (CNT-4_theoretical). The graph shows the evolution of the stress in the stay cable due to the concreting of the successive arch segments and the stressing of the successive provisional stay cables.

Evolution of the effort experienced by the fourth stay cable family.

Due to the problems encountered in the measurements of the direct methodologies explained above for the first two families of cables of the Tajo River Viaduct, the authors proposed to carry out a weighing campaign of the cables belonging to these families using the vibrating wire technique. This technique makes it possible the measurement of the stress in bridge cables by characterising their vibration frequency and their mass19,57,58. The differential equation that relates the axial stress of a cable to its mass, its bending stiffness and its vibration frequency is as follows:

The solution Eq. (3) to the differential Eq. (2) allows for the axial stress of the cable to be obtained.

The bending stiffness (E·I) in the bridge cables is negligible with respect to their axial stiffness. This fact makes the second and third sums of Eq. (3) negligible with respect to the first, resulting in Eq. (4) that relates the axial stress of the cable to its mass and frequency19 of oscillation. Figure 9 shows the evolution of the error committed, assuming the simplification set forth in Eq. (4), for each of the families of temporary stay cables of the Tajo River Viaduct, as a function of the stress experienced by these structural elements.

where T = Axial stress on the cable; u = Considered vibration mode; f = Vibration frequency corresponding to u-mode; E = Modulus of elasticity of the material composing the cable; I = Moment of inertia of the cable; L = Vibration length of the cable; m = Mass per linear meter of the cable.

Evolution of the error committed by the simplified formulation of the vibrating wire: (a) north suspension cables; (b) north retaining cables; (c) south suspension cables; (d) south retaining cables.

To carry out the weighing of the cables using the vibrating wire technique, a piezoelectric accelerometer was installed on the cable under test by means of a tool which picks up the sheath–strand assembly, excites the cable and measures the accelerations experienced by the cable during its movement in free vibration are measured. To obtain the axial stress of the cable by applying Eq. (4), it is necessary to consider the total mass moved. In the case of the temporary cables of the Tajo River Viaduct, it was necessary to consider the mass of the strands making up the cable together with the mass of the protective sheath (see Fig. 10). Another important parameter for the correct determination of the stress in bridge stay cables by means of the vibrating wire technique is the length of the stay cable. In the case of the Tajo Bridge Viaduct stay cables, this length was obtained by means of topography. The records of the acceleration experienced by the cables were analyzed by applying the Fast Fourier Transform58,59,60,61, obtaining the eigenfrequencies of the cables, and consequently their axial stress (see Fig. 11).

Piezoelectric accelerometer on the temporary tie of the Tajo Viaduct.

Obtaining the stresses in the fifth stay cable family from their vibration frequencies: (a) accelerogram; (b) frequency spectrum.

Due to previous experience with the construction of similar bridges8,60,62,63,64 in which episodes of confluence between the frequency of vortex generation by the action of the wind on the structure and its vibration frequency occurred, the vibrating wire testing campaign was used to obtain the damping factor of the cables of the Tajo River Viaduct. In order to obtain the damping factor (see Fig. 12), the test consisted in subjecting the cable to an initial tension by applying a displacement to its main span and then releasing it abruptly, leaving it to oscillate in a free vibration regime. Obtaining this parameter made it possible to update the calculation model of the structure and to predict the behaviour of the stay cables in the event of possible aeroelastic phenomena. Table 1 shows the value of the damping factor obtained for the first two families of suspension and retaining cables. The damping factor of the cable is obtained from the logarithmic decrease between maximum amplitudes of its oscillation during free vibration, see Eq. (5)65:

where η = Damping factor with respect to the critical; n = Number of cycles considered for the analysis; A0 = Maximum amplitude in the initial oscillation considered for the analysis; An = Maximum amplitude in the nth oscillation considered for the analysis.

Retrieval of the damping factor of the right-hand retaining cable of the fifth family of temporary cables of the northern half arch of the Tajo River Viaduct: (a) recording of accelerations associated with the first mode of vibration; (b) speed record; c) displacement record.

Seeking a dual purpose, the authors proposed a solution that would make it possible to monitor the evolution of stresses in the cable and to characterise the possible appearance of aeroelastic phenomena caused by resonance or similar phenomena8,60,62,63,64. This solution consisted of the permanent instrumentation of the right-hand retaining cable belonging to the fifth family of temporary cables of the northern half arch of the Tajo River Viaduct (N-T-5d). For this purpose, a piezoelectric accelerometer was installed on the selected cable using a tool identical to the one used in the vibrating wire spot testing campaign, and this sensor was connected to the SMS of the Tajo River Viaduct. Figure 13 shows the monitoring of the evolution of stresses in the cable obtained from the analysis of the data provided by the piezoelectric accelerometer.

Monitoring of the evolution of the stresses in the right-hand retaining cable belonging to the fifth family of temporary cables of the northern half arch of the Tajo River Viaduct (N-T-5d) using a piezoelectric accelerometer.

The simultaneous instrumentation of the first two families of stay cables by means of load cells and unidirectional strain gauges installed in one of the strands that make up the stay cable, together with the campaign to weigh the stay cable by means of the vibrating wire technique, allowed a comparative analysis of the stress provided for each of the structural monitoring techniques. Figure 14 and Table 2 show the stress provided by each of the structural monitoring techniques used by the authors.

Effort facilitated by each of the structural monitoring techniques used.

The lessons learned during Tajo’s Viaduct monitoring through the installation of the different sensor technologies can be summarised as follows (see Table 3):

Strain gauge load cells

Advantages:

Allows measurement of the stress on the cables with an error of less than 1%.

Robust solution, shock-resistant, and weather-resistant solution.

Disadvantages:

It represents the largest economic investment.

Instrumentation of heavy-duty cables involves the design of large, very heavy load cells which are difficult to handle and install on-site.

Installation is only possible prior to the cable installation operation.

Unidirectional strain gauges

Advantages:

Technique involving the lowest economic investment.

Installation is possible at any stage of the construction process.

Disadvantages:

Less robust solution, very sensitive to shocks and weather.

In the case of installation, once in service, the cable provides the stress increments on the structural element, but it is not possible to obtain the absolute value of the stress in the cable.

The accuracy of the measurement of stress on the cables is strongly influenced by the correct on-site installation of the device.

Unidirectional accelerometers

Advantages:

Installation is possible at any stage of the construction process.

Allows the recording of the absolute value of the stress on the cable stress regardless of the phase of the construction process in which the sensor has been installed.

Allows measurement of the stress in the cables with an error of less than 1%.

Disadvantages:

Technique generates a high volume of data and it is necessary to resort to spectral decomposition techniques to obtain the stress on the cable.

Thanks to this work, the authors aim to give an overview of the different monitoring systems used currently used for temporary cable force monitoring techniques during bridge construction phase. For this purpose, a review of the state of the art has been carried out. An overview between load cells, unidirectional strain gauges systems and accelerometers has also been provided. All of these methods are well established and very accurate. However, each of them has its own advantages and disadvantages in terms of installation and implementation. The most promising technique under development nowadays is image-based and can be seen as complementary to these currently available methods. Today, this technique cannot provide the same level of accuracy as current methods, but it is cheap and simple to use compared to the accelerometer, i.e. further development is still needed before it can be implemented on long-span cable-stayed bridges because their behavior is not trivial. Indeed, the long-span bridges are susceptible to environmental and traffic-induced vibration.

With all these points in mind, this article is intended to serve as a basis for all work related to the world of cable monitoring during bridge construction.

The data that support the findings of this study are available from the corresponding author, Gaute A., upon reasonable request.

Tabatai, H. Transportation Research Board, Inspection and Maintenance of Bridge Stay Cable Systems (National Cooperative Highway Research Program, 2005).

Google Scholar

Yang, D.-H., Yi, T.-H., Li, H.-N. & Zhang, Y.-F. Correlation-based estimation method for cable-stayed bridge girder deflection variability under thermal action. J. Perform. Constr. Facil. https://doi.org/10.1061/(ASCE)CF.1943-5509.0001212 (2018).

Article Google Scholar

Tang, T., Yang, D.-H., Wang, L., Zhang, J.-R. & Yi, T.-H. Design and application of structural health monitoring system in long-span cable-membrane structure. Earthq. Eng. Eng. Vib. 18(2), 461–474. https://doi.org/10.1007/s11803-019-0484-y (2019).

Article Google Scholar

Nong, S.-X., Yang, D.-H. & Yi, T.-H. Pareto-based bi-objective optimization method of sensor placement in structural health monitoring. Buildings 11, 549. https://doi.org/10.3390/buildings11110549 (2021).

Article Google Scholar

Yang, Y., Li, S., Nagarajaiah, S., Li, H. & Zhou, P. Real-time output-only identification of time-varying cable tension from accelerations via complexity pursuit. J. Struct. Eng. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001337 (2016).

Article Google Scholar

Ni, Y. Q., Wong, K. Y. & Xia, Y. Health checks through landmark bridges to sky-high structures. Adv. Struct. Eng. 14, 103–119. https://doi.org/10.1260/1369-4332.14.1.103 (2011).

Article Google Scholar

Nagarajaiah, S. & Yang, Y. Blind modal identification of output-only non-proportionally-damped structures by time-frequency complex independent component analysis. Smart Struct. Syst. 15, 81–97. https://doi.org/10.12989/sss.2015.15.1.081 (2015).

Article Google Scholar

Olson, D. W., Wolf, S. F. & Hook, J. M. The Tacoma Narrows Bridge collapse. Phys. Today 68(11), 64–65. https://doi.org/10.1063/PT.3.2991 (2015).

Article Google Scholar

Mehrabi, A. B. In-service evaluation of cable-stayed bridges, overview of available methods, and findings. J. Bridg. Eng. 11, 716–724. https://doi.org/10.1061/(ASCE)1084-0702(2006)11:6(716) (2006).

Article Google Scholar

Xu, F., Wang, X. & Wu, H. Inspection method of cable-stayed bridge using magnetic flux leakage detection: principle. Sens. Des. Signal Process. 26(3), 661–669. https://doi.org/10.1007/s12206-011-1234-x (2012).

Article Google Scholar

Caro, L., Martí-Vargas, J. & Serna, P. Prestress losses evaluation in prestressed concrete prismatic specimens. Eng. Struct. 48, 704–715. https://doi.org/10.1016/j.engstruct.2012.11.038 (2013).

Article Google Scholar

Freddi, A., Olmi, G., & Cristofolini, L. Introduction to the application of strain gages. In Experimental Stress Analysis for Materials and Structures (Springer, 2015) 23–100. https://doi.org/10.1007/978-3-319-06086-6_2.

Guo, T., Chen, Z., Lu, S. & Yao, R. Monitoring and analysis of long-term prestress losses in post-tensioned concrete beams. Measurement 122, 573–581. https://doi.org/10.1016/j.measurement.2017.07.057 (2018).

Article ADS Google Scholar

Martí-Vargas, J., Caro, L. & Serna, P. Experimental technique for measuring the long-term transfer length in prestressed. Strain 49(2), 125–134. https://doi.org/10.1111/str.12019 (2013).

Article Google Scholar

Varatharajoo, R. et al. Load cell application in rocket thrust measurement system. Appl. Mech. Mater. 225, 437–441. https://doi.org/10.4028/www.scientific.net/AMM.225.437 (2012).

Article Google Scholar

Li, H., Ou, J. & Zhou, Z. Applications of optical fibre Bragg gratings sensing technology-based smart stay cables. Opt. Lasers Eng. 47, 1077–1084. https://doi.org/10.1016/j.optlaseng.2009.04.016 (2009).

Article Google Scholar

Wang, G., Wang, M., Zhao, Y., Chen, Y. & Sun, B. Application of magnetoelastic stress sensors in large steel cables. Smart Struct. Syst. 2, 155–169. https://doi.org/10.1007/1-4020-3661-2_15 (2006).

Article Google Scholar

Sumitro, S., Matsui, Y., Kono, M., Okamoto, T. & Fuji, K. Long span bridge health monitoring system in Japan. In 6th Annual International Symposium on NDE for Health Monitoring and Diagnostics. Health monitoring and management of civil Infrastructure, Vol. 4337. University of California. https://doi.org/10.1117/12.435628 (2001).

Casas, J. A combined method for measuring cable forces: The cable-stayed Alamillo Bridge, Spain. Struct. Eng. Struct. Dyn. 4(4), 235–240. https://doi.org/10.2749/101686694780601700 (1994).

Article Google Scholar

Zui, H., Shinke, T. & Namita, Y. Practical formulas for estimation of cable tension by vibration method. J. Struct. Eng. 122, 651–656. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:6(651) (1996).

Article Google Scholar

Russel, J. C. & Lardner, T. J. Experimental determination of frequencies and tension for elastic cables. J. Eng. Mech. 124, 1067–1072. https://doi.org/10.1061/(ASCE)0733-9399(1998)124:10(1067) (1998).

Article Google Scholar

Ren, W. X., Chen, G. & Hu, W. H. Empirical formulas to estimate cable tension by cable fundamental frequency. Struct. Eng. Mech. 20, 363–380. https://doi.org/10.12989/sem.2005.20.3.363 (2005).

Article Google Scholar

Kim, B. H. & Taehyo, P. Estimation of cable tension force using the frequency-based system identification method. J. Sound Vib. 304, 660–676. https://doi.org/10.1016/j.jsv.2007.03.012 (2007).

Article ADS Google Scholar

Liao, W. Y., Ni, Y. Q. & Zheng, G. Tension force and structural parameter identification of bridge cables. Adv. Struct. Eng. 15, 983–995. https://doi.org/10.1260/1369-4332.15.6.983 (2012).

Article Google Scholar

Antoni, J. Blind separation of vibration components: Principles and demonstrations. Mech. Syst. Signal Process. 19, 1166–1180. https://doi.org/10.1016/j.ymssp.2005.08.008 (2005).

Article ADS Google Scholar

Kerschen, G., Poncelet, F. & Golinval, J. C. Physical interpretation of independent component analysis in structural dynamics. Mech. Syst. Signal Process. 21, 1561–1575. https://doi.org/10.1016/j.ymssp.2006.07.009 (2007).

Article ADS Google Scholar

Yang, Y. & Nagarajaiah, S. Output-only modal identification with limited sensors using sparse component analysis. J. Sound Vib. 332, 4741–4765. https://doi.org/10.1016/j.jsv.2013.04.004 (2013).

Article ADS Google Scholar

Yang, Y. & Nagarajaiah, S. Structural damage identification via a combination of blind feature extraction and sparse representation classification. Mech. Syst. Signal Process. 45, 1–23. https://doi.org/10.1016/j.ymssp.2013.09.009 (2014).

Article ADS Google Scholar

Yang, Y. & Nagarajaiah, S. Time-frequency blind source separation using independent component analysis for output-only modal identification of highly damped structures. J. Struct. Eng. 139, 1780–1793. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000621 (2016).

Article Google Scholar

Poncelet, F., Kerschen, G., Golinval, J. C. & Verhelst, D. Output-only modal analysis using blind source separation techniques. Mech. Syst. Signal Process. 21, 2335–2358. https://doi.org/10.1016/j.ymssp.2006.12.005 (2007).

Article ADS Google Scholar

Abazarsa, F., Ghahari, S. F., Nateghi, F. & Taciroglu, E. Response-only modal identification of structures using limited sensors. Struct. Control. Health Monit. 20, 987–1006. https://doi.org/10.1002/stc.1513 (2013).

Article Google Scholar

Leung, C. et al. Optical fiber sensors for civil engineering applications. Mater. Struct. 48(4), 871–906. https://doi.org/10.1617/s11527-013-0201-7 (2015).

Article Google Scholar

Inaudi, D. Application of optical fiber sensor in civil structural monitoring. Smart structures and materials 2001: Sensory phenomena and measurement instrumentation for smart structures and materials. Int. Soc. Opt. Photonics https://doi.org/10.1117/12.435512 (2001).

Article Google Scholar

Glisic, B., Inaudi, D. & Vurpillot, S. Whole lifespan monitoring of concrete bridges. In First International Conference on Bridge Maintenance, Safety and Management. IABMAS'02. Barcelona (2002).

Glisic, B. Influence of the gauge length on the accuracy of long-gauge sensors employed in monitoring of prismatic beams. Meas. Sci. Technol. https://doi.org/10.1088/0957-0233/22/3/035206 (2011).

Article Google Scholar

Capineri, L. & Bulletti, A. Ultrasonic guided-waves sensors and integrated structural health monitoring systems for impact detection and localization: A review. Sensors 21, 2929. https://doi.org/10.3390/s21092929 (2021).

Article ADS CAS PubMed PubMed Central Google Scholar

Glisic, B. One hundred years of strain sensing in civil structural health monitoring health monitoring. In 12th International Workshop on Structural Health Monitoring: Enabling Intelligent Life-Cycle Health Management for Industry Internet of Things (IIOT), IWSHM 2019. Stanford (2019).

Bado, M. F. & Casas, J. R. A review of recent distributed optical fiber sensors applications for civil engineering structural health monitoring. Sensors 21, 1818. https://doi.org/10.3390/s21051818 (2021).

Article ADS CAS PubMed PubMed Central Google Scholar

Laarossi, I. et al. Ultrahigh temperature Raman-based distributed optical fiber sensor with gold-coated fiber. IEEE J. Sel. Top. Quantum Electron. 23(2), 296–301. https://doi.org/10.1109/JSTQE.2016.2633821 (2017).

Article ADS Google Scholar

Bado, M. F., Casas, J. R. & Kaklauskas, G. Distributed Sensing (DOFS) in Reinforced Concrete members for reinforcement strain monitoring, crack detection and bond-slip calculation. Eng. Struct. https://doi.org/10.1016/j.engstruct.2020.111385 (2021).

Article Google Scholar

Lu, P. et al. Distributed optical fiber sensing: Review and perspective. Appl. Phys. Rev. https://doi.org/10.1063/1.5113955 (2019).

Article Google Scholar

Schenato, L. A review of distributed fibre optic sensors for geo-hydrological applications. Appl. Sci. https://doi.org/10.3390/app7090896 (2017).

Article Google Scholar

Eschmann, C. & Wundsam, T. Web-based georeferenced 3D inspection and monitoring of bridges with unmanned aircraft systems. J. Surv. Eng. https://doi.org/10.1061/(ASCE)SU.1943-5428.0000221 (2017).

Article Google Scholar

Olaszek, P. Investigation of the dynamic characteristic of bridge structures using a computer vision method. Measurement 25(3), 227–236. https://doi.org/10.1016/S0263-2241(99)00006-8 (1999).

Article ADS Google Scholar

Patsias, S. & Staszewskiy, W. J. Damage detection using optical measurements and wavelets. Struct. Health Monit. 1(1), 5–22. https://doi.org/10.1177/147592170200100102 (2002).

Article Google Scholar

Yoshida, J., Abe, M., Kumano, S. & Fujino, Y. Construction of a measurement system for the dynamic behaviors of membrane by using image processing. In International Conference on Textile Composites and Inflatable Structures. Structural Membranes (2003).

Chun, H.-C., Liang, J., Kushiyama, S. & Shinozuka, M. Digital image processing for non-linear system identification. Int. J. Non-Linear Mech. 39(5), 691–707. https://doi.org/10.1016/S0020-7462(03)00021-0 (2004).

Article MATH Google Scholar

Chang, C. C. & Ji, Y. Sensing of low-frequency vibration using photogrammetric technique. In Structural Health Monitoring and Intelligent Infrastructure: Proceedings of the 2nd International Conference on Structural Health Monitoring of Intelligent Infrastructure, SHMII 2005. Shenzhen (2006).

Ji, Y. F. & Chang, C. C. Nontarget image-based technique for small cable vibration measurement. J. Bridg. Eng. 13(1), 34–42. https://doi.org/10.1061/(ASCE)1084-0702(2008)13:1(34) (2008).

Article Google Scholar

Manterola-Armisen, J., Martínez-Cutillas, A. & Martín-Martínez, B. Puente sobre el río Tajo en el embalse de Alcántara para ferrocarril de alta velocidad. Revista de Obras Públicas 3562, 83–92 (2015).

Google Scholar

Mundo-Ferroviario. Viaducto de Alcántara, un arco de 324 metros de luz para salvar el Tajo. https://www.mundo-ferroviario.es (2013).

Dally, J. & Riley, W. F. Experimental Stress Analysis (McGraw-Hil Book Company, 1978). https://doi.org/10.1016/0142-1123(81)90011-6.

Book Google Scholar

Pantaleón, M. J. & Gutiérrez, G. Apuntes de extensometría y fotoelasticidad (Universidad de Cantabria, 1983).

Google Scholar

Hoffmann, K. An introduction to stress analysis and transducer design using strain gauges. HBM https://doi.org/10.1111/j.1475-1305.2001.tb01242.x (2012).

Article Google Scholar

Iriarte, X., Aginaga, J., Gainza, G., Ros, J. & Bacaicoa, J. Optimal strain-gauge placement for mechanical load estimation in circular cross-section shafts. Measurement 174, 108938. https://doi.org/10.1016/j.measurement.2020.108938 (2021).

Article Google Scholar

Castillo Linares, A., Ramos Gutiérrez, Ó. R., Díaz García, M. Á. & Pantaleón Prieto, M. J. Structural site supervision about erection procedure and temporary works in the Constitución de 1812 Bridge over the Cadiz Bay: General aspects and specific cases of study. Hormigón y Acero 67(278–279), 277–285. https://doi.org/10.1016/j.hya.2016.02.006 (2016).

Article Google Scholar

González, S., Désir, J., Habib, P. & Vieira, C. Theorical and experimental checking of remaining forces in external prestessing tendons. Hormigón y Acero 58(245), 93–102 (2007).

Google Scholar

Ferreras, D., Martí, R. & Somalo, J. Inspección especial Pasarela Atirantada El Perelló. Hormigón y Acero 63(266), 67–78 (2012).

Google Scholar

Gentile, C. & Saisi, A. Ambient vibration testing and conditon assessment of the Padermo iron arch bridge (1889). Constr. Build. Mater. 25(9), 3709–3720. https://doi.org/10.1016/j.conbuildmat.2011.04.019 (2011).

Article Google Scholar

Barrero, A., Alonso, G., Meseguer, J. & Astiz, M. Ensayos en túnel de viento de un modelo aeroelástico del arco del Puente sobre el río Tajo. Arcos de Alconétar. Hormigón y Acero 245, 33–40 (2007).

Google Scholar

Henderson, G. Wind-Induced Vibration of Stay Cables (U.S. Department of Transportation. Federal Highway Administration, 2007).

Google Scholar

Arioli, G. & Gazzola, F. Torsional instability in suspension bridges: The Tacoma Narrows Bridge case. Commun. Nonlinear Sci. Numer. Simul. 42, 342–357. https://doi.org/10.1016/j.cnsns.2016.05.028 (2017).

Article ADS MathSciNet MATH Google Scholar

Astiz, M. A. Wind-induced vibrations of the Alconétar Bridge, Spain. Struct. Eng. Int. 20(2), 195–199. https://doi.org/10.2749/101686610791283696 (2018).

Article Google Scholar

Fei, H., Zichen, D. & Danhui, D. Exact dynamic analysis of multi-segment cable systems. Mech. Syst. Signal Process. 146, 107053. https://doi.org/10.1016/j.ymssp.2020.107053 (2021).

Article Google Scholar

General Highway Administration - Government of Spain, Recomendaciones para la realización de pruebas de carga de recepción en puentes de carretera (1999).

Download references

The authors would like to thank “Administración de Infraestructuras Ferroviarias ADIF” (Administrator of Railway Infrastructures) for trusting the University of Cantabria’s Structures Laboratory to carry out the structural monitoring of the Tajo River Viaduct. This work has received funding from the European’s Union Horizon 2020 research and innovation program under the Grant Agreement No. 769373 (FORESEE project). This paper reflects only the author’s views. The European Commission and INEA are not responsible for any use that may be made of the information contained therein.

Grupo de Instrumentación y Análisis Dinámico de Estructuras, University of Cantabria, Santander, Spain

Alvaro Gaute-Alonso

TECNALIA Basque Research and Technology Alliance (BRTA), Derio, Spain

David Garcia-Sanchez & Iñigo Calderon-Uriszar-Aldaca

Structural and Mechanical Engineering Area, University of Cantabria, Santander, Spain

Carlos Alonso-Cobo

University of Navarra, Pamplona, Spain

Iñigo Calderon-Uriszar-Aldaca

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

Conceptualisation, A.G.-A., D.G.-S., C.A.C. and I.C.-U.-A.; methodology A.G.-A. and D.G.-S.; validation A.G.-A. and D.G.-S; formal analysis, A.G.-A. and D.G.-S.; investigation, A.G.-A. and D.G.-S.; resources, D.G.-S. and I.C.-U.-A.; writing—original draft preparation, A.G.-A. and D.G.-S.; writing—review and editing, C.A.C. and I.C.-U.-A.; supervision, A.G.-A., D.G.-S., C.A.C. and I.C.-U.-A.; project administration, A.G.-A. and D.G.-S.; funding acquisition, D.G.-S., C.A.C. and I.C.-U.-A. All authors have read and agreed to the published version of the manuscript.

Correspondence to Alvaro Gaute-Alonso.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and Permissions

Gaute-Alonso, A., Garcia-Sanchez, D., Alonso-Cobo, C. et al. Temporary cable force monitoring techniques during bridge construction-phase: the Tajo River Viaduct experience. Sci Rep 12, 7689 (2022). https://doi.org/10.1038/s41598-022-11746-z

Download citation

Received: 24 November 2021

Accepted: 11 April 2022

Published: 11 May 2022

DOI: https://doi.org/10.1038/s41598-022-11746-z

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

Scientific Reports (2023)

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.